Railways & Metro

About

Railway and metro infrastructure faces vibration, dynamic loads, moisture, abrasion, and continuous operational stress. From platforms and depot floors to precast components and underground works, concrete must resist cracking and perform reliably over time.

Glassman AR Glass Fibres by DD Solutions help improve concrete durability by controlling micro-cracks, reducing permeability, improving surface integrity, and supporting long-term serviceability. For rail and metro projects, Glassman works best where crack control, clean finishing, and non-corrosive reinforcement are priorities.

Why Glassman for

Railways & Metros Projects?

Rail infrastructure does not get much rest. Concrete in these environments must perform under movement, vibration, moisture, and daily service loads.

Glassman AR Glass Fibres help improve the concrete matrix by reducing micro-crack development and supporting durability. This helps reduce surface deterioration and improves the service performance of non-primary structural concrete elements, platforms, floors, precast products, and repair sections.

Key Benefits

Controls Micro-Cracking

Controls Micro-Cracking

Helps reduce shrinkage and early crack development.

Improves Durability

Improves Durability

Supports lower permeability and improved long-term performance.

Non-Corrosive

Non-Corrosive

Suitable for underground, depot, platform, and drainage-related applications.

Improves Surface Quality

Improves Surface Quality

Helps create cleaner finishes for platforms, floors, and precast units.

Supports Abrasion Resistance

Supports Abrasion Resistance

Useful for depot floors, maintenance yards, walkways, and service areas.

Easy to Integrate

Easy to Integrate

Can be added to concrete mixes without major changes to production workflow

Typical Applications

Usage & Mixing Guildlines

Quality Standards

Recommended Fibre Types

Glassman AR Glass Fibre – 12mm

Suitable for platforms, floors, walkways, precast units, and general concrete applications.

Glassman AR Glass Fibre – 16mm

Suitable for thicker slabs and enhanced crack-control applications, subject to technical approval.

Suggested Dosage

0.5 kg to 1.0 kg per m³ of concrete

Final dosage should depend on application, concrete grade, exposure condition, finishing requirement, and project specification.

Technical Note

Recommended dosage and fibre length should always be finalized based on the application, mix design, site conditions, and trial results.

For structural replacement of steel reinforcement, project-specific validation by a qualified engineer is required.